1,
cut off disc the machine is not running (no refrigeration or pump does not effect)
Check that the power cord is connected to the power plug;
Check that the power switch is turned on;
Check the panel power is turned on.
2, the pump does not work
Check the liquid level of the system to ensure that the pump receives liquid;
Check pump motor is running;
Check the circulatory system is clogged;
3, inadequate suction pump
Check if the voltage is too low;
Check that the tube diameter is too small;
Check whether the fluid viscosity is too high;
Check the connection pipe is restricted.
4, no refrigeration or inadequate refrigeration
Check if the voltage is too low or too high;
Check whether the ventilation blockage;
Check the ambient temperature (ambient temperature is too high will cause a momentary stop of refrigeration compressors;)
Check if too much heat is transferred to the cooling liquid, because this would exceed the cooling capacity of the refrigeration system.